Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Korean Journal of Fertility and Sterility ; : 229-236, 2006.
Article in Korean | WPRIM | ID: wpr-217377

ABSTRACT

OBJECTIVE: We investigated the expression of uPA and uPAR in eutopic endometrium of advanced stage endometriosis and control patients. METHODS: The 33 endometriosis patients and 32 controls were enrolled. Endometrial samples were obtained from 65 premenopausal women aged 29~44 years, undergoing laparoscopic surgery or hysterectomy for non-malignant lesions. Sufficient samples were collected from 33 patients with endometriosis stage III and IV and 32 controls without endometriosis confirmed by laparoscopic surgery. The mRNA expression of uPA and uPAR from eutopic endometrium were analyzed by RT-QC PCR. RESULTS: The mRNAs of uPA and uPAR were expressed in eutopic endometrium from endometriosis and normal controls throughout the menstrual cycle. Uterine endometrium from women with endometriosis expresses significantly (p<0.05) higher levels of u-PA mRNA than endometrium from normal women without endometriosis in the proliferative phase. There were no significant differences in expression of uPAR in eutopic endometrium between controls and endometriosis patients. CONCLUSION: These results suggest that eutopic endometrium from endometriosis patients may be more invasive and prone to peritoneal implantation because of greater u-PA mRNA expression than endometrium from women without endometriosis. Thus, increased proteolytic activity may be one etiology for the invasive properties of the endometrium resulting in the development of endometriosis.


Subject(s)
Female , Humans , Endometriosis , Endometrium , Hysterectomy , Laparoscopy , Menstrual Cycle , Polymerase Chain Reaction , Proteolysis , RNA, Messenger , Urokinase-Type Plasminogen Activator
2.
Journal of the Korean Society of Emergency Medicine ; : 133-139, 1999.
Article in Korean | WPRIM | ID: wpr-225538

ABSTRACT

Prediction of individual outcome after cardiopulmonary resuscitation is of major medical, ethical, and socioeconomic interest but uncertain. We experienced the case thats the patient got complete neurologic recovery after the 123th day firm cardiac arrest, who had been suspected to go with poor prognosis because she got the findings of Glasgow Coma Scale 4, severe diffuse encephalopathy on encephalogram and generalized tonic-clonic seizure at the 4th day. Recently, a 29 year-old women who sustained from respiratory arrest induced presumably by sedative and anticonvulsant therapy for control of seizure that happened during local lidocaine anesthesia far mamoplasty was transfered to our emergency medical center from local private plastic office. Arrest time was about 20 minutes. On hospital arrival, she had a pulseless bradyasystole and no respiration, but spontaneous circulation was restored at 10 minutes artier CPR started. We started cerebral oriented resuscitation including mild hypothermia(34degrees C), hemodilution, calcium channel blocker infusion. On hospital day 4, patient's glasgow coma scale(GCS) was 4. On hospital clay 7, Brain Magnetic Resonance Imaging(MRI) showed high signal intensity on T2WI, involving the bilateral basal ganglia. After contrast administraton, marked enhancement can be seen at the lesion site. Patient's glasgow coma scale(GCS) increased step by step to 5 on 8th day, 7 on 14th day, 10 on 15th day, 13 on 17th day, 15 on 20th day. 40 days later the patient was discharged with minor neurologic abnormality including hand tremor, dysphonia, amenorrhea and Mini Mental State Examination(MMSE) score(26). Long-term Follow up revealed that all neurologic functional abnormality inducting hand tremor, dysphonia, amenorrhea and MMSE score(26) is completely recovered on 123th day after episode of cardiopulmonary arrest.


Subject(s)
Adult , Female , Humans , Amenorrhea , Anesthesia , Basal Ganglia , Brain , Calcium Channels , Cardiopulmonary Resuscitation , Coma , Dysphonia , Emergencies , Follow-Up Studies , Glasgow Coma Scale , Hand , Heart Arrest , Hemodilution , Hypoxia-Ischemia, Brain , Lidocaine , Plastics , Prognosis , Respiration , Resuscitation , Seizures , Tremor
3.
Journal of the Korean Society of Emergency Medicine ; : 499-504, 1997.
Article in Korean | WPRIM | ID: wpr-164826

ABSTRACT

BACKGROUND: Nitrous oxide is a safe analgesics which has analgesic and sedative effects without loss of consciousness. The advantage of Nitrous oxide is that it has a rapid onset time and that we can modulate duration of its action. The purpose of this experiment is to obtain the safe and effective concentration of Nitrous oxide in Emergency Department as use of analgesics and sedative drugs. METHODS: Twenty volunteers were investigated according to double blind method. Nitrous oxide was administrated to volunteer subjects at different concentrations ; 33%, 50%, 67% each. Then we evaluated the Pain score, Blood pressure, Heart rate, Respiratory rate, Oxygen saturation and its side effects. RESULTS: Pain Score were 8.4+/-2.1 at 33%, 6.1+/-1.5 at 50%, and 3.65+/-2.2 at 67% of Nitrous oxide. Pain Score is decreased significantly following administration of Nitrous oxide at concentration of 50%, 67%(P<0.05). There was no difference between preadministration group and postadministration group. While no remarkable change in systolic blood pressure, heart rate, and oxygen saturation. Respiratory rate showed significant increase when 679o of Nitrous oxide was administrated. There was no side effect in administration of 33% of Nitrous oxide. When 50% of Nitrous oxide was administrated, there were dizziness 5(25%), paresthesia 2(10%), nausea 1(5%), palpitation 1(5%) and hyperethesia 1(5%). At 679o of Nitrous oxide, there were nausea 7(35%), dizziness 6(30%), paresthesia 5(25%), headache 5(25%), diplopia 2(10%), dysphoria 2(10%), salivation 1(5%), dyspnea 1(5%), nystagmus 1(5%), tinnitus 1(5%) and euphoria1 (5%). Incidence of side effect increased as the concentration of Nitrous oxide was increased. CONCLUSION: We can conclude that safe and effective concentration of Nitrous oxide is 50% as analgesics and sedative drugs in the emergency department.


Subject(s)
Analgesics , Blood Pressure , Diplopia , Dizziness , Double-Blind Method , Dyspnea , Emergency Service, Hospital , Headache , Heart Rate , Hemodynamics , Hypnotics and Sedatives , Incidence , Nausea , Nitrous Oxide , Oxygen , Paresthesia , Respiratory Rate , Salivation , Tinnitus , Unconsciousness , Volunteers
SELECTION OF CITATIONS
SEARCH DETAIL